Sensor
Long range distance sensors Sick Dx500 / DS500
Type:DS500-P611
Part No.:1040480
Part No.:1040480
Mechanics/electronics
Performance
Interfaces
Ambient data
Classifications
Supply voltage Vs |
DC 10 V ... 30 V, reverse polarity protected UV ≥ DC 24 V for devices with heating |
Ripple | 5 Vpp 1) |
Power consumption | Typ. 22 W |
Initialization time | 500 ms |
Housing material | Metal (Aluminum die cast) |
Window material | Glass |
Connection type | Male connector, M12, 5-pin |
Weight | 1,000 g |
Dimensions (W x H x D) | 69 mm x 50 mm x 153 mm |
Enclosure rating | IP65 |
Protection class | II 2) |
- 1) May not fall short of or exceed VS tolerances.
- 2) Reference voltage DC 32 V.
Performance
Measuring range |
0.2 m ... 70 m, 90 % remission 1) 2) 0.2 m ... 30 m, 6 % remission 1) 2) |
Target | Natural objects |
Resolution | ≤ 1 mm |
Repeatability | 1 mm |
Accuracy | ± 3 mm |
Response time | 150 ms ... 6,000 ms |
Output time | 150 ms ... 6,000 ms |
Light source | Laser, red 3) visible red light |
Laser class | 2, complies with 21 CFR 1040.10 and 1040.11 except for the conformance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1:2014, EN 60825-1:2014) |
Typ. light spot size (distance) |
10 mm (at 7 m) 45 mm (at 30 m) 100 mm (at 70 m) |
- 1) In ambient light, max. 1 klx of constant light.
- 2) Unique up to 150 m.
- 3) Average service life of 50,000 h at TA = +25 °C.
Interfaces
|
|||||||||
Multifunctional input (MF) | < 2 V 2) 3) | ||||||||
Hysteresis | ± 6 % |
- 1) PNP: HIGH = VS - (< 2.5 V) / LOW = < 2.5 V; NPN: HIGH = < 2.5 V / LOW = VS.
- 2) Refer to function MF input.
- 3) NPN < 2 V.
Ambient data
Electromagnetic compatibility (EMC) |
EN 61000-6-2, EN 55011 EN 60947-5-7: 2003-9 |
Ambient temperature, operation |
–40 °C ... +45 °C, operation with heating –40 °C ... +75 °C, operation with cooling case |
Ambient temperature, storage | –25 °C ... +75 °C |
Temperature drift | Typ. 0.05 mm/K |
Typ. Ambient light immunity | ≤ 3,000 lx |
Mechanical load |
Shock: (EN 600 68-2-27) Sine: (EN 600 68-2-6) Noise: (EN 600 68-2-64) |
Classifications
ECl@ss 5.0 | 27270801 |
ECl@ss 5.1.4 | 27270801 |
ECl@ss 6.0 | 27270801 |
ECl@ss 6.2 | 27270801 |
ECl@ss 7.0 | 27270801 |
ECl@ss 8.0 | 27270801 |
ECl@ss 8.1 | 27270801 |
ECl@ss 9.0 | 27270801 |
ECl@ss 10.0 | 27270801 |
ECl@ss 11.0 | 27270801 |
ETIM 5.0 | EC001825 |
ETIM 6.0 | EC001825 |
ETIM 7.0 | EC001825 |
ETIM 8.0 | EC001825 |
UNSPSC 16.0901 | 41111613 |