    Omron PLC CS Series Analog I/O Units CS1W-MAD44

    Omron PLC


     
    Item CS1W-MAD44
    Applicable PLC model CS series
    Unit type CS1 Special I/O Unit
    Isolation Between I/O and PLC signals: Photocoupler (No isolation between individual I/O signals.)
    External terminals 21-point detachable terminal block (M3 screws)
    Power consumption 200 mA max. at 5 VDC, 200 mA max. at 26 VDC
    Dimensions (mm) *1 35 ´ 130 ´ 126 (W ´ H ´ D)
    Weight 450 g max.
    General specifications Conforms to general specifications for SYSMAC CS-series Series.
    Mounting position CS-series CPU Rack or CS-series Expansion Rack

     

    (Cannot be mounted to a C200H Expansion I/O Rack or a SYSMAC BUS Slave Rack.)

     

     

     

     

    Maximum number of Units

     

     

     

    Units per Rack (CPU Rack or Expansion Rack) *2

    Power Supply Unit Maximum number of Units per Rack
        C200HW-PA204 C200HW-PA204S C200HW-PA204R C200HW-PD024  

     

    3 Units max.

        C200HW-PA209R 6 Units max.
      Units per basic system When C200HW-PA209R Power Supply Units only are used: 6 Units max. ´ 8 Racks = 48 Units max.
     

     

     

     

     

     

    Data exchange with CPU Units

     

     

    Special I/O Unit Area

    CIO 200000 to CIO 295915

    (Words CIO 2000 to CIO 2959)

     

     

     

    Exchanges 10 words of data per Unit.

    CPU Unit to Analog I/O Unit Analog output Peak value hold

     

    Conversion Enable Bit

          Analog I/O Unit to CPU Unit Analog input

     

    Input disconnection detection Alarm flags

       

     

     

    Internal Special I/O Unit DM Area (D20000 to D29599)

     

     

     

    Transmits 100 words of data per Unit at power-up or when the Unit is restarted.

     

     

     

    CPU Unit to Analog I/O Unit

    Input signal conversion enable/disable, input signal range setting

     

    Output signal conversion enable/disable, output signal range setting

    Ratio conversion function setting, constants

    Output status for output hold Mean value function setting

     

     

     

     

     

     

     

     

     

     

     

    Input Specifications

    Input signal *4 Voltage input Current input
      Number of analog inputs 4
       

     

    Input signal range *3

    1 to 5 V

     

    0 to 5 V

    0 to 10 V

    -10 to 10 V

     

     

    4 to 20 mA

      Maximum rated input (for 1 point) *5 ±15 V ±30 mA
      Input impedance 1 MΩ min. 250 Ω (rated value)
      Resolution 4,000 (full scale)
      Converted output data 16-bit binary data
      Accuracy *6 23±2°C ±0.2% of full scale ±0.4% of full scale
        0°C to 55°C ±0.4% of full scale ±0.6% of full scale
      A/D conversion time *7 1.0 ms/point max.
     

     

     

    Functions

     

     

    Mean value processing

    Stores the last “n” data conversions in the buffer, and stores the the mean value of the conversion values.

     

    Buffer number: n = 2, 4, 8, 16, 32, 64

      Peak value holding Stores the maximum conversion value while the Peak Value Hold Bit is ON.
      Input disconnection detection *9 Detects the disconnection and turns ON the Disconnection Detection Flag.