    Omron PLC CS Series Analog Input Units CS1W-AD041-V1/AD081-V1/AD161

    Omron PLC


     
    Item CS1W-AD041-V1 CS1W-AD081-V1 CS1W-AD161
    Applicable PLC model CS series
    Unit type CS1 Special I/O Unit
    Isolation *1 Between I/O and PLC signals: Photocoupler (No isolation between individual I/O signals.)
    External terminals 21-point detachable terminal block (M3 screws) Two 34-pin MIL connectors
    Affect on CPU Unit cycle time 0.2 ms
    Power consumption 120 mA max. at 5 VDC, 90 mA max. at 26 VDC 150 mA max. at 5 VDC,

     

    55 mA max. at 26 VDC

    Dimensions (mm) *2 35 ´ 130 ´ 126 (W ´ H ´ D) 35 ´ 130 ´ 119 (W ´ H ´ D)
    Weight 450 g max.
    General specifications Conforms to general specifications for SYSMAC CS Series.
    Mounting position CS-series CPU Rack or CS-series Expansion Rack

     

    (Cannot be mounted to a C200H Expansion I/O Rack or a SYSMAC BUS Slave Rack.)

    Maximum number of Units Depends on the power supply Unit. *3
     

     

     

    Data exchange with CPU Units *4

     

     

     

    Special I/O Unit Area in CIO Area (CIO 2000 to CIO 2959): 10 words per Unit Special I/O Unit Area in DM Area (D20000 to D29599): 100 words per Unit

    Special I/O Unit Area in CIO Area (CIO 2000 to CIO 2959): 20 words per Unit

     

    Special I/O Unit Area in DM Area (D20000 to D29599): 200 words per Unit

    Number of analog inputs 4 8 16
     

     

     

    Input signal range *5

    1 to 5 V

     

    0 to 5 V

    0 to 10 V

    -10 to 10 V 4 to 20 mA

    *6

    Maximum rated input (for 1 point) *7 Voltage Input: ±15 V Current Input: ±30 mA
    Input impedance Voltage Input: 1 MΩ min.

     

    Current Input: 250 Ω (rated value)

    Resolution 4,000/8,000 *8
    Converted output data 16-bit binary data
    23±2°C Voltage Input: ±0.2% of full scale Current Input: ±0.4% of full scale Voltage Input: ±0.2% of full scale Current Input: ±0.2% of full scale
    0°C to 55°C Voltage Input: ±0.4% of full scale Current Input: ±0.6% of full scale Voltage Input: ±0.4% of full scale Current Input: ±0.4% of full scale
    A/D conversion time *10 1.0 ms or 250 ms per point max. *8
    Mean value processing Stores the last “n” data conversions in the buffer, and stores the mean value of the conversion values. Buffer number: n = 2, 4, 8, 16, 32, 64
    Peak value holding Stores the maximum conversion value while the Peak Value Hold Bit is ON.
    Input disconnection detection Detects the disconnection and turns ON the Disconnection Detection Flag. *11
     

     

     

    Scaling function

     

     

     

    None

     

     

     

    None

    Enabled only for conversion time of 1 ms and resolution of 4,000. Setting any values within a range of ±32,000

     

    as the upper and lower limits allows the A/D conversion result to be output with these values as full scale.

     