Sensor
Rectangular W Cable Type 250 Mm Keyence LR-ZB250AP
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
*3 Have passed resistance tests with cleaning agents from multiple manufactures.
*4 When the response time is 10 ms
Model |
LR-ZB250AP |
|||
Type |
Distance based laser sensor |
|||
Appearance |
Rectangular |
|||
Output |
PNP |
|||
Cable connection |
2 m cable |
|||
Detectable distance |
35 to 250 mm 1.38" to 9.84" (215 to 0)*1 |
|||
Standard detectable deviation |
35 to 180 mm 1.38" to 7.09": 9 mm 0.35" |
|||
Display resolution |
1 to 3 (1 to 3 mm 0.04" to 0.12") |
|||
Spot size |
Approx. 2.4 × 1.2 mm 0.09" × 0.05" at 250 mm 9.84" |
|||
Response time |
1.5 ms / 10 ms / 50 ms selectable |
|||
Light source |
Type |
Red laser (660 nm) |
||
Laser class |
Class 1 laser product (IEC60825-1, FDA (CDRH) Part1040.10*2) |
|||
Function |
Indicator |
3-digit 7-segment display (red), output indicator (yellow), DATUM indicator (orange), 1 spot indicator (green) |
||
Timer |
OFF/ON delay/OFF delay/One-shot |
|||
Specifications |
Power voltage |
10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
||
Power consumption |
450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V) |
|||
Control output |
PNP Open collector, Applied voltage 30 VDC or less, Control current 100 mA or less, Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, reverse output connection |
|||
Output operation |
Light-ON / Dark-ON selectable |
|||
External input |
Input time calibration: 35 ms or more ON, 35 ms or more OFF |
|||
Environmental resistance |
Enclosure rating |
IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3 |
||
Insulation resistance |
20 MΩ or more (500 VDC) |
|||
Ambient light |
Incandescent lamp: 2,000 lux or less |
|||
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Storage temperature |
-25 to +75 °C -13 to 167 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Withstand voltage |
1,000 VAC, 50/60 Hz, 1 min |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, Packing/Connector ring: FKM |
|||
Accompanying items |
Instruction Manual, Certification/Identification label (FDA) |
|||
Weight |
Approx. 110 g (Including cable) |
|||
*1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed. |