Sensor
Model |
CZ-V21AP*1 |
|||
Output |
PNP output |
|||
Main unit/expansion unit |
Main unit |
|||
Response time |
200 µs (HIGH SPEED) /1 ms (FINE) /4 ms (TURBO) /8 ms (SUPER) |
|||
Control output |
PNP open-collector x 4 channels, 30 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*2 |
|||
Protection circuit |
Reverse-polarity protection, overcurrent protection, surge absorber |
|||
External tuning input, external bank switch input (C/C + I-mode), external shift input (super I-mode) |
Input time: 20 ms min. |
|||
Timer function |
Timer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively) |
|||
Unit expansion |
Up to 3 units (4 units total including the main unit) |
|||
Number of interference prevention units |
0 for HIGH SPEED; 2 for FINE/TURBO/SUPER |
|||
Rating |
Power voltage |
24 VDC, Ripple (P-P) 10 % or less |
||
Power consumption |
Normal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less) |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing)*3 |
||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Housing, cover: Polycarbonate |
|||
Accessories |
Mounting Fittings |
|||
Weight |
Approx. 110 g |
|||
*1 The expansion unit of the FS-V20 Series cannot be connected to the main unit of the CZ-V20 Series. To connect the FS and CZ Series units, connect the expansion unit of the CZ-V20 Series to |