Model |
IG-010 |
|||
Operation principle |
CCD method |
|||
Light source |
Wavelength |
660 nm (Visible light semiconductor laser) |
||
FDA |
Class 1*1 |
|||
IEC/JIS |
Class 1 |
|||
Mounting distance |
0 to 1000 mm 39.37" |
|||
Measurement range |
10 mm 0.39" |
|||
Sampling cycle |
980 µs (When the number of times for averaging is set to [hsp]: 490 µs) |
|||
Minimum detectable object |
High sensitivity mode |
ø0.1 mm ø0.003" (Setting distance: 100 mm 3.94")*2 |
||
Standard mode |
ø0.2 mm ø0.007" (Setting distance: 40 mm 1.57" or less), ø0.5 mm ø0.02" (Setting distance: 500 mm 19.68")*2 |
|||
Repeatability |
5 µm 0.20 Mil (Setting distance: 100 mm 3.94") |
|||
Linearity |
±0.28 % of F.S. (±28 µm ±1.10 Mil)*4 |
|||
Temperature characteristics |
±0.03 % of F.S./°C (±3 µm ±0.12 Mil/°C)*5 |
|||
Operation indicator |
Transmitter |
Optical axis alignment indicator: Green LED, Power indicator: Green LED |
||
Receiver |
Optical axis alignment indicator: Green LED, Position monitor: Dual bar LED (Red, Green) |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient light |
Incandescent lamp: 5,000 lux, Sunlight: 5,000 lux*6 |
|||
Ambient temperature |
-10 to +45 °C 14 to 113 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Case |
Zinc die-cast (Lower case), PBT (Upper case), Polyarylate (PAR) (Display part), SUS304 (Metallic part) |
||
Lens cover |
Glass |
|||
Cable |
PVC |
|||
Accessories |
Transmitter × 1, Receiver × 1, Sensor head cables (2 m 6.56') × 2 |
|||
Weight |
Approx. 380 g (including supplied items) |
|||
*1 The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. |